• Home
  • List of Papers
  • Calibration of Tooth Profile Measurement and Uncertainty Analysis Based on Ball Artifact Method

Calibration of Tooth Profile Measurement and Uncertainty Analysis Based on Ball Artifact Method

Abstract

Tooth profile measurements were calibrated using a double ball artifact that is traceable to a national standard of length. From the calibrated results, an evaluation technology that quantifies the uncertainty of tooth profile measurement in a 1-to-1 correspondence with a tooth profile of arbitrary specifications was established. In this evaluation technology, the work of calibrating the measuring machine has been minimized, and measurement simulations have been made feasible by modeling the statistical properties, as well as algebraic calculation from the model during tooth profile measurement, enabling the reliability of tooth profile measurement to be statistically evaluated. As a result, during tooth profile inspections on the manufacturing floor, practical inspection accuracy is now guaranteed.

References

  1. (1) Kubo, A., Komori, M.: Kyoukitansin, No. 3 p. 1-2 (2004) (in Japanese)
  2. (2) Kondo, K.: A new proposal of primary artifact for calibration of gear measuring machines and calibration method, The Japan Society of Mechanical Engineers Bibliography, Vol. 8, p. 508-515 (2005)
  3. (3) Nakagawa, T., Koyanagi, Y.: Saisho Jijyou Hou niyoru Jikken Deeta Kaiseki, Toukyou Daigaku Shuppan, p. 35 (1982) (in Japanease)
  4. (4) Shinozaki, H., Matsushita, Y.: Ouyou Suuchi Keisanhou Nyuumon (Jyou), Korona Sha, p. 175 (1976) (in Japanease)
  5. (5) Zhang, G.: A Displacement Method for Machine Geometry Calibration, Annals of the CIRP, Vol. 37, No. 1, p. 515-517 (1998)
  6. (6) BIPM, IEC, IFCC, ISO, IUPAC, IUPAP, OIML: Guide to the expression of uncertainty in measurement, ISO, First edition (1993)
  7. (7) Kondo, Y., Noguchi, S., Kondo, K., Osawa, S., Naoi, K., Takatsuji, T., Kurosawa, T.: Tooth Form Evaluation Using Ball Artifact: Development of a Measuring Instrument of Ball Center Distance Traceable to National Standard of Length, Journal of the Japan Society for Precision Engineering, Vol. 71, No. 10, p. 1260-1265
  8. (8) Tanaka, H., Shimojo, M., Kajitani, M., Sato, T., Takeda, R., Kojima, M., Yuzaki, M., Kato, S., Shibuya, Y., Kondo, T.: Evaluation of measurement uncertainty in gear measuring instruments by the Monte Carlo simulation, The American Society for Precision Engineering, Proceedings of the Eighteen Annual Meeting, p. 395-398 (2003)

Author (organization or company)

Publication Information

Article of Honda R&D Technical Review Vol.19 No.2 (152 - 163)

PDF

PDF 432KB

Citation Information

Kenta UMETSU, Wataru ISHIDO, Kinya FUJIWARA.
Calibration of Tooth Profile Measurement and Uncertainty Analysis Based on Ball Artifact Method
Honda R&D Technical Review Vol.19 No.2 pp.(152 - 163)2007.
Copy citation information
Copied